Changeset 1044 for papers


Ignore:
Timestamp:
04/04/13 13:55:42 (12 years ago)
Author:
wojtekp
Message:
 
File:
1 edited

Legend:

Unmodified
Added
Removed
  • papers/SMPaT-2012_DCWoRMS/review/reviewers_remarks

    r957 r1044  
    1515 
    1616Some questions : 
    17 -page 7 : for workload modeling : is it possible to use SWF file and XML file for the same simulation ? 
     17-page 7 : for workload modeling : is it possible to use SWF file and XML file for the same simulation ? +++++ 
    1818-page 18 : I think there are mistakes in the sections referenced : the static model is presented in section 4.2 ? the dynamic one in section 4.3 ? and the mapping in section 4.4 ? 
    1919-table 8 : the EO+NPM give the same results as R is it normal ? 
     
    3131 
    3232Detailed comments 
    33 -Section 2:What is the meaning of the phrase: 'imposes and restricts users in terms of modeled resources'? Explain or rephrase to make the contribution of the paper clear 
     33-Section 2:What is the meaning of the phrase: 'imposes and restricts users in terms of modeled resources'? Explain or rephrase to make the contribution of the paper clear++++ 
    3434-Section 3.4: No explanation of how 'thermal issues' are taken into account is presented in the experimental section. 
    3535-Section 3.2-3.5: It would be useful to provide a short concise summary about which information should be the input to the simulator by the user, how the tool deals with this input and what are the outputs. 
    3636-Section 5.4: The question that arises here is how hard/realistic it is to run each application on each type of node for all frequencies  in advance in order to use the mapping approach. It would be useful to show the results from these measurements and show how the equation (7) fits on these data.    
    3737In this context, it would be interesting to run the simulations for the case that the model of equation (7) is used, and show whether the energy optimization techniques result in real savings or not due to the model errors. 
    38 -Section 5.4: Please provide some explanation on table 5. 
     38-Section 5.4: Please provide some explanation on table 5.++++ 
    3939-Section 5.5.1: Figures 6 and especially the Gannt charts in all cases are impossible to read. It would be more useful to present a 'zoom in'  for a specific case to show the information that this chart holds. 
    4040-Section 5.5.3: It would be interesting to show or comment on the existence of a 'critical' slow-down frequency above which the slow down is indeed energy efficient despite the longer execution times. 
    41 -Section 5.6: In the tables it appears that less load has greater energy usage and makespan values than the respective values of greater load. Please explain. 
     41-Section 5.6: In the tables it appears that less load has greater energy usage and makespan values than the respective values of greater load. Please explain.++++ 
    4242 
    4343 
Note: See TracChangeset for help on using the changeset viewer.