Changeset 1247 for DCWoRMS/branches/coolemall/src/example/energy
- Timestamp:
- 11/28/13 10:54:54 (11 years ago)
- Location:
- DCWoRMS/branches/coolemall/src/example/energy
- Files:
-
- 6 edited
Legend:
- Unmodified
- Added
- Removed
-
DCWoRMS/branches/coolemall/src/example/energy/DataCenterEnergyEstimationPlugin.java
r1207 r1247 1 1 package example.energy; 2 2 3 import schedframe.resources.computing. ComputingNode;3 import schedframe.resources.computing.Node; 4 4 import schedframe.resources.computing.DataCenter; 5 5 import schedframe.resources.computing.profiles.energy.EnergyEvent; … … 15 15 double power = 0; 16 16 DataCenter dataCenter = (DataCenter)resource; 17 for( ComputingNode cn:dataCenter.getComputingNodes()){17 for(Node cn:dataCenter.getNodes()){ 18 18 PowerUsage powerUsage = cn.getPowerInterface().getRecentPowerUsage(); 19 19 power += (powerUsage == null ? 0 : powerUsage.getValue()); -
DCWoRMS/branches/coolemall/src/example/energy/NodeEnergyEstimationPlugin.java
r1207 r1247 1 1 package example.energy; 2 2 3 import schedframe.resources.computing. ComputingNode;3 import schedframe.resources.computing.Node; 4 4 import schedframe.resources.computing.Processor; 5 5 import schedframe.resources.computing.profiles.energy.EnergyEvent; … … 13 13 PhysicalResource resource) { 14 14 double powerConsumption = 0; 15 ComputingNode node = (ComputingNode) resource;15 Node node = (Node) resource; 16 16 for(Processor cpu: node.getProcessors()){ 17 17 try{ -
DCWoRMS/branches/coolemall/src/example/energy/coolemall/CB2EnergyEstimationPlugin.java
r1207 r1247 3 3 4 4 import schedframe.resources.StandardResourceType; 5 import schedframe.resources.computing.Node; 5 6 import schedframe.resources.computing.ComputingResource; 6 7 import schedframe.resources.computing.Processor; 7 8 import schedframe.resources.computing.coolemall.ComputeBox1; 8 import schedframe.resources.computing.coolemall.Node;9 9 import schedframe.resources.computing.coolemall.NodeGroup; 10 10 import schedframe.resources.computing.profiles.energy.EnergyEvent; -
DCWoRMS/branches/coolemall/src/example/energy/coolemall/HeatsinkEnergyEstimationPlugin.java
r1207 r1247 1 1 package example.energy.coolemall; 2 2 3 import schedframe.resources.computing. ComputingNode;3 import schedframe.resources.computing.Node; 4 4 import schedframe.resources.computing.Processor; 5 5 import schedframe.resources.computing.profiles.energy.EnergyEvent; … … 16 16 double powerConsumption = 0; 17 17 Device device = (Device) resource; 18 ComputingNode cn = (ComputingNode) device.getComputingResource();18 Node cn = (Node) device.getComputingResource(); 19 19 for(Processor proc : cn.getProcessors()){ 20 20 powerConsumption = powerConsumption + proc.getPowerInterface().getRecentPowerUsage().getValue(); -
DCWoRMS/branches/coolemall/src/example/energy/coolemall/NodeEnergyEstimationPlugin.java
r1207 r1247 1 1 package example.energy.coolemall; 2 2 3 import schedframe.resources.computing.Node; 3 4 import schedframe.resources.computing.Processor; 4 import schedframe.resources.computing.coolemall.Node;5 5 import schedframe.resources.computing.profiles.energy.EnergyEvent; 6 6 import schedframe.resources.computing.profiles.energy.power.StandardPowerStateName; -
DCWoRMS/branches/coolemall/src/example/energy/coolemall/NodeGroupEnergyEstimationPlugin.java
r1207 r1247 1 1 package example.energy.coolemall; 2 2 3 import schedframe.resources.computing. coolemall.Node;3 import schedframe.resources.computing.Node; 4 4 import schedframe.resources.computing.coolemall.NodeGroup; 5 5 import schedframe.resources.computing.profiles.energy.EnergyEvent;
Note: See TracChangeset
for help on using the changeset viewer.